StrucLab
| Project | — | Job No. | — |
| Calculation | Pad Footing Reinforcement Rate | By | — |
| Reference | Estimating rate (indicative) | Date | 6 June 2026 |
Pad Footing Reinforcement Rate
Estimating · Reinforcement mass, kg/m² and kg/m³ for an isolated pad footing
59.9Rate by area (kg/m²)
49.9Rate by volume (kg/m³)
1,811Total reo mass (kg)
Breakdown
Bar mass per AS/NZS 4671 standard masses.
| Item | No. | Bar | Length (m) | Mass (kg) |
|---|---|---|---|---|
| Layer A | 28 | N28 | 6.172 | 856.3 |
| Layer B | 28 | N28 | 6.172 | 856.3 |
| Starter bars | 8 | N28 | 2.494 | 98.9 |
| Total | — | 1,811.5 |
Quantities
| Plan area | 30.25 m² | W × L |
| Concrete volume | 36.30 m³ | area × D |
| Starter lap length | 1,150 mm | by bar Ø |