AS/NZS 1170.0:2002 · Strength, stability & serviceability combinations ready to paste into analysis software
Actions present

ψs=0.7 · ψl=0.4 · ψc=0.4 · ψE=0.3 (Table 4.1)

Strength (ULS)

AS/NZS 1170.0 Cl 4.2.2 — basic combinations for checking strength.

No.CombinationClauseDescription
11.35 G4.2.2(a)Permanent only
21.2 G + 1.5 Q4.2.2(b)Permanent + imposed
31.2 G + 0.6 Q4.2.2(c)Permanent + long-term imposed (ψl=0.4)
41.2 G + Wu + 0.4 Q4.2.2(d)Permanent + wind + imposed (ψc=0.4)
50.9 G + Wu4.2.2(e)Permanent + wind reversal

Stability (ULS)

Cl 4.2.1 — stabilising and destabilising combinations.

No.CombinationClauseDescription
10.9 G4.2.1(a)Net stabilising
21.35 G4.2.1(b)(i)Net destabilising
31.2 G + 1.5 Q4.2.1(b)(ii)Destabilising + imposed
41.2 G + Wu + 0.4 Q4.2.1(b)(iv)Destabilising + wind (ψc=0.4)

Serviceability (SLS)

Cl 4.3 / Appendix C — common serviceability combinations. Confirm the appropriate SLS condition for your check.

No.CombinationClauseDescription
1GSLS-1Permanent (long-term)
2G + 0.7 QSLS-2Short-term imposed (ψs=0.7)
3G + 0.4 QSLS-3Long-term imposed (ψl=0.4)
4G + Ws + 0.4 QSLS-4Wind + long-term imposed (ψl=0.4)

Symbols: G permanent, Q imposed, Wu ultimate wind, Ws serviceability wind, Eu earthquake, Su earth/liquid pressure. Combinations follow AS/NZS 1170.0 Section 4 with ψ factors from Table 4.1. Indicative — confirm the governing actions and any project-specific combinations for your design. Verify independently.